Expert calibration lab in
Elizabeth City, North Carolina

Opening hours

Mon
07:30 - 04:00
Tue
07:30 - 04:00
Wed
07:30 - 04:00
Thu
07:30 - 04:00
Fri
07:30 - 04:00
Contact
(252) 337-9975
108 Enterprise Drive
Elizabeth City, NC 27909

ACCREDITATIONS

ISO/IEC 17025

ANSI/NCSL Z540.1

ANSI/NCSL Z540.3

 

Scope of accreditation
A2LA Cert #2737.02

A2LA Cert #2737.02

ISO/IEC 17025

ISO/IEC 17025

ANSI/NCSL Z540.1

ANSI/NCSL Z540.1

ANSI/NCSL Z540.3

ANSI/NCSL Z540.3

CAPABILITIES

Accredited Capabilities
Traceable Capabilities
Electricity
Torque
Time / Frequency
Pressure / Vacuum
Dimensional
Fiber Optics
Electricity

Electricity

Accredited Capabilities

Global Calibration Scope

  • 0.1A to 5000A AC & DC
  • Ration Rx:Rs
  • 1mΩ to 1GΩ (CMC 3µΩ to 25µΩ)
  • 1kVrms to 85kVrms @ 60 Hz

Common equipment serviced: Digital Multimeters, Oscilloscope, Power supplies, LCR Meters, Megohmmeter, Insulation Testers, Function Generator, Power Quality, Ohmmeters, Clamp Meter, Standard Resistors, Hipots, High voltage meter

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Torque

Accredited Capabilities

Global Calibration Scope

  • 2.0ozf.in to 2000lbf.ft

Common equipment serviced: Torque sensors,Torque Tools, Torque Testers & Transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Time / Frequency

Accredited Capabilities

Global Calibration Scope

  • 10MHz w/GPS Receiver
  • 1 to 120 000 RPM
  • 55 to 40 000 RPM
  • ± (0 to 19.99) sec/day (CMC 0.037 sec/day)

Common equipment serviced: Frequency Measure, RPM Optical, RPM Mechanical, Stopwatches & Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Pressure / Vacuum

Accredited Capabilities

Global Calibration Scope

  • (-15 to 0) psig
  • (1 to 15) psia
  • (0 to 30) psig
  • (30 to 100) psig
  • (100 to 1000) psig
  • (1000 to 5000) psig
  • (5000 to 10 000) psig

Common equipment serviced: Pressure – Measuring Equipment3, Pneumatic (Vacuum & Gage), Hydraulic

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Dimensional

Accredited Capabilities

Global Calibration Scope

  • Diameters external: -up to 3″
  • Lengths: up to 12″

Common equipment serviced: Plug gauges, Pin gauges, Length standards

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Fiber Optics

Fiber Optics

Accredited Capabilities

EQUIPMENT TYPES

Fiber optics transmit light signals encoded with data. Trescal calibrates a range of fiber optics including:

 

  • Sources
    • LED
    • LASER
  • Optical
    • Optical Power Meters
    • Optical Time Domain Reflectometers
    • Optical Loss Test Sets
    • Optical Spectrum Analyzers
    • Optical Return Loss Meters
  • Extinction Ratio Meters
  • Polarimeters

CALIBRATION SCOPE

 

  • Power – Source and Measure
    • +30 dBm to -110 dBm (600 to 1750 nm)
  • Wavelength – Source and Measure
    • 600 to 1750 nm
  • Linearity
    • 0 to -110 dB (633 nm, 650 nm, 850 nm, 1300 nm, 1310 nm, 1550 nm and 1625 nm)
  • OTDR Distance
    • 300 ft, 3000 m, 25 km, 50 km, 100 km (Multimode: 300ft and 3000 m only)
  • Optical Return Loss
    • 10 to 65 db (1310 nm and 1550 nm)
  • Fiber Optic Cable Length
    • Single mode: 0 to 300 km
    • Multimode: 0 to 100 km
Electricity

Global Calibration Scope

  • 0.1A to 5000A AC & DC
  • Ration Rx:Rs
  • 1mΩ to 1GΩ (CMC 3µΩ to 25µΩ)
  • 1kVrms to 85kVrms @ 60 Hz

Common equipment serviced: Digital Multimeters, Oscilloscope, Power supplies, LCR Meters, Megohmmeter, Insulation Testers, Function Generator, Power Quality, Ohmmeters, Clamp Meter, Standard Resistors, Hipots, High voltage meter

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Torque

Global Calibration Scope

  • 2.0ozf.in to 2000lbf.ft

Common equipment serviced: Torque sensors,Torque Tools, Torque Testers & Transducers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Time / Frequency

Global Calibration Scope

  • 10MHz w/GPS Receiver
  • 1 to 120 000 RPM
  • 55 to 40 000 RPM
  • ± (0 to 19.99) sec/day (CMC 0.037 sec/day)

Common equipment serviced: Frequency Measure, RPM Optical, RPM Mechanical, Stopwatches & Timers

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Pressure / Vacuum

Global Calibration Scope

  • (-15 to 0) psig
  • (1 to 15) psia
  • (0 to 30) psig
  • (30 to 100) psig
  • (100 to 1000) psig
  • (1000 to 5000) psig
  • (5000 to 10 000) psig

Common equipment serviced: Pressure – Measuring Equipment3, Pneumatic (Vacuum & Gage), Hydraulic

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Dimensional

Global Calibration Scope

  • Diameters external: -up to 3″
  • Lengths: up to 12″

Common equipment serviced: Plug gauges, Pin gauges, Length standards

This site holds the competency for the specified domain. If your requirement is outside the scope of competency, we may be able to transfer the instrument with your permission to another Trescal laboratory that holds the applicable scope. Please refer to the scope of accreditation for accredited capabilities specific to this laboratory.

Fiber Optics